FTL-FM1 ctg machine 12.1 Inches Monitor Fetal Doppler Electronic Fetal Heart Monitoring Wireless Fetal Monitor Fetal Baby Monitor

FTL-FM1 ctg machine 12.1 Inches  Monitor Fetal Doppler Electronic Fetal Heart  Monitoring Wireless Fetal Monitor Fetal Baby Monitor

Performance Specifications
Dimension360mm*310mm*120mm
Weight5.3kg(excluding accessories)
Power SupplyVoltage AC100~240V, 50/60HZ
Display12.1" color TFT LED (0-90° rotation) Resolution 1024*768 pixels
Battery (Built-in)Type Rechargeable lithium battery 14.8V/2200mAh
Charge Cycle≥500 times
Working time2 hours
Recorder (Built-in)
MethodThermal printer
PaperZ-fold, thermosensitive
Paper width112 mm (4.41 in)/150 mm (5.91 in)
Printing speed1/2/3cm/min
TraceMax. 4 tracks
-Recording wayReal-time Recording, Review Printing
Alarm
LevelLow, medium and high
IndicationAuditory, Visual, Delay of FHR Alarm
Input Device
-Touch screen (option)
-Knob (Standard)
-Keypad input (Standard)
Mouse/Keyboard input (option)
-USB port for patient data/NST report backup (option)
System Output & Extensible Interface
-Ethernet Network1 standard RJ45 socket
-USB Port2
-Video Output1 HDMI port (option)
Trend & Reviewing
-Cardiotocography (CTG)
Waveform Review8640 hours
-Vital Signs
Trend2160 hours
Waveform Review2 hours
NIBP Review2000 groups
-Alarm Review2000 groups
Safety
-IEC60601-1 Approved, CE marking according to MDD93/42/EEC
-With reference to RoHS Directive 2011/65/EU recasting
-Ultrasound (FHR)
-Transducer type12-Crystal ultrasound transducer
-Measure methodWide beam pulse doppler
-FHR Measurement range
30 to 240 bpm (US Standard)
50 to 210 bpm (Europe Standard)
Accuracy±1 bpm
Intensity<3 mW/cm2
-Ultrasound frequency1MHz±3%
Resolution1 bpm
TOCO
-Measurement methodStrain gauge sensor element
-Measure range0 ~ 100 units
Resolution1 unit
-Nonlinear deviation≤±8%
-Baseline setting0,5,10,15, 20 can be selected
-Auto offset correction3 second after connecting the transducer
-Auto zero adjustTOCO value is set to zero negative following a negative Measure value for 5 seconds
Fetal Movement Recording
-Automatic fetal movement (AFM)pulsed doppler ultrasound
-Automatic fetal movement autograph
-Manual fetal movement marker (MFM)
Maternal ECG
-Lead mode3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
A63Gain2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV, Auto
Sweep speed6.25mm/s, 12.5mm/s, 25mm/s, 50 mm/s
Accuracy±1bpm/ ±1%, whichever is greater
Resolution1 bpm
Leakage Current < 10 μA
CMRRDiagnostic Mode >89 dB

Monitor Mode >105 dB

Surgery Mode >105 dB
BandwidthSurgery 1 ~ 25 Hz

Monitor 0.5 ~ 40 Hz

Diagnostic 0.05 ~ 120 Hz
Maternal Heart Rate
-Measure rangeAdult:0bpm; 10 ~ 300 bpm

Neonate:0bpm; 10 ~ 350 bpm
Resolution1 bpm
Accuracy± 1% or ± 1bpm, whichever is greater
ST Measurement
Range-2.0 ~ +2.0 mV
Accuracy-0.8mV~+0.8mV:±0.02mV or ±10%, whichever is greater
-Other rangeunspecified
Resolution0.01mV
Maternal Respiration
MethodImpedance between RA-LL, RA-LA
Gain×0.25, ×0.50, ×1, ×2, ×4
-Respiration Rate0bpm, 6 ~ 150 bpm
Resolution1 bpm
Accuracy±2 bpm or ±2%, whichever is greater
-Apnea Alarm10 ~ 60 s
Maternal SpO2 (Digital Technic)
-Measurement Range0 ~ 100 %
Resolution1%
Accuracy±2% (70% ~ 100%)
±3 % (35% ~ 69%)
Unspecified (0 ~ 34%)
Pulse Rate
Range25~250bpm
Accuracy±1% or ±1 bpm, whichever is greater
Resolution1bpm
Maternal NIBP (MNIBP)
MethodOscillometric
-Measure mode Manual, Auto, STAT
-Measure Interval in AUTO Mode 1~480 min
-STAT mode cycle time
-Keep 5 minutes, at 5 seconds interval
-Measure and Alarm Range
Systolic30~270 mmHg
Diastolic10~220 mmHg
Mean20~235 mmHg
-Static pressure accuracy ±3mmHg
Resolution1mmHg
AccuracyMaximum Mean error ±5mmHg
Maximum Standard deviation 8mmHg
-Over pressure ProtectionDual protection via software & hardware
Maternal Temperature
TechniqueThermistor probe (2.25K)
-Measuring and Alarm Range0.0 ℃~ 50 ℃ (32℉~ 122℉)
UnitCelsius (℃), Fahrenheit ( ℉)
Resolution0.1℃
Accuracy±0.1℃
NST Report/FHR Interpretation (Option)
-Based on Fischer Evaluation Method (monitoring time≥20 Min)
-Average Baseline FHR /Number of Acceleration /Number of Deceleration /Number of Small Acceleration /Amplitude Variation /Number
of PV
-Automatic Score ResultScore 8-10 (Excellent)
Score5-7 (Suspicious)
Score ≤4 ( Fetus Hypoxia)


Model NumberFTL-FM1
Power SourceElectricity
Materialmetal, Plastic, Steel
Shelf Life1years
Product nameFetal Monitor
Display12.1 Inch LED
BatteryRechargeable lithium battery 14.8V/2200mAh
FunctionMedical Examination
purposeExamination department
Resolution1024*768 pixels

The specific parameters should be based on what the sales representative provides



Product introduction

17331279684585664.jpg

17337973571605011.png

Fatali Medical Technology Foshan Co.,Ltd is a 21 years professional experience medical equipment supplier.



.


Detailed presentation
FM1 Foetal and maternity monitor

Newly advanced A9 main board with Linux OS, calculating speed is 4 times faster than traditional products

12.1 inch Folded high-brightness TFT LED(Optional touch screen)

12-Crystal ultrasound transducer achieves a wider focal region for more uniform coverage at greater depths than conventional 9-crystal

Built-in high-speed thermal printer, printing width can be set to 112mm, 150mm